MOXA NPort 5400 Serial Device Servers
NPort 5400 Series - General Device Servers
- User-friendly LCD panel for easy installation
- Adjustable termination and pull high/low resistors
- Socket modes: TCP server, TCP client, UDP
- Configure by Telnet, web browser, or Windows utility
- SNMP MIB-II for network management
- 2 kV isolation protection for NPort 5430I/5450I/5450I-T
- -40 to 75 C operating temperature range (-T model)
NPort 5410 | NPort 5430 | NPort 5430i | NPort 5450 | |
Serial Interface | RS-232 | RS-422/485 | RS-422/485 | RS-232/422/485 |
Serial Interface Connector | DB9 male | Terminal block | Terminal block | DB9 male |
Serial Interface Isolation | ?? | ?? | 2 kV | ?? |
Operating Temp. | 0 to 55 C | 0 to 55 C | 0 to 55 C | 0 to 55 C |
Input Voltage | 12 to 48 VDC | 12 to 48 VDC | 12 to 48 VDC | 12 to 48 VDC |
Introduction
NPort 5400 device servers provide many useful features for serial-to-Ethernet applications, including an independent operation mode for each serial port, user-friendly LCD panel for easy installation, dual DC power inputs, and adjustable termination and pull high/low resistors.
Network Readiness for up to 4 Serial Devices
NPort 5400 device servers can conveniently and transparently connect up to four serial devices to an Ethernet network, allowing you to network your existing serial devices with only basic configuration. Data transmission between the serial and Ethernet interfaces is bidirectional. By using NPort device servers, you not only protect your current hardware investment, but also allow for future network expansion. You can both centralize the management of your serial devices and distribute management hosts over the network.
Independent Operation Mode for Each Serial Port
NPort 5400 device servers can be used to connect different devices for remote data polling or event handling over a TCP/IP network. Each serial port on the NPort 5400 operates independently to provide maximum versatility. For example, port 1 can operate in Driver mode, port 2 in TCP Server mode, and ports 3 and 4 in TCP Client mode.
User-friendly LCD Panel for Easy Installation
An LCD panel is built into the NPort 5400's top panel, with four buttons for data input, configuration, and operation mode selection. The LCD panel displays the server name, serial number, and IP address, and it can be used to enter or modify parameters such as IP address, netmask, and gateway. (The LCD panel is not available on wide-temperature models.)
Dual DC Power Inputs
NPort 5400 device servers support dual power sources by providing both a DC terminal block input and a DC power jack input. Providing two types of power inputs gives users greater flexibility for use with different applications.
Adjustable Termination and Pull High/Low Resistors
The NPort 5400 Series provides adjustable termination and pull high/low resistors for RS-485 applications. In some critical environments, termination resistors may be needed to prevent the reflection of serial signals, and the pull high/low resistors may need adjusting to maintain the integrity of the electrical signal. Since no set of resistor values is universally compatible with all environments, the NPort 5400 has four sets of DIP switches on the bottom panel to set the termination and pull high/low resistor values.
Ethernet Interface
10/100BaseT(X) Ports (RJ45 connector)
1
Magnetic Isolation Protection
1.5 kV (built-in)
Ethernet Software Features
Configuration Options
Telnet Console, Windows Utility, Web Console (HTTP/HTTPS)
Management
ARP, BOOTP, DHCP Client, DNS, HTTP, HTTPS, ICMP, IPv4, LLDP, Rtelnet, SMTP, SNMPv1/v2c, TCP/IP, Telnet, UDP
Filter
IGMP v1/v2
Windows Real COM Drivers
Windows 95/98/ME/NT/2000, Windows XP/2003/Vista/2008/7/8/8.1/10 (x86/x64), Windows 2008 R2/2012/2012 R2/2016/2019 (x64), Windows Embedded CE 5.0/6.0, Windows XP Embedded
Linux Real TTY Drivers
Kernel versions: 2.4.x, 2.6.x, 3.x, 4.x, and 5.x
Fixed TTY Drivers
SCO UNIX, SCO OpenServer, UnixWare 7, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX 5.x, HP-UX 11i, Mac OS X
Android API
Android 3.1.x and later
Time Management
SNTP
Serial Interface
Connector
NPort 5410/5450/5450-T/5450I/5450I-T: DB9 male
NPort 5430/5430I: Terminal blockNo. of Ports
4
Serial Standards
NPort 5410: RS-232
NPort 5430 Series: RS-422, RS-485
NPort 5450 Series: RS-232, RS-422, RS-485Operation Modes
Disabled, Ethernet Modem, Pair Connection, Real COM, Reverse Telnet, TCP Client, TCP Server, UDP
Baudrate
Supports standard baudrates (unit=bps): 50, 75, 110, 134, 150, 300, 600, 1200, 1800, 2400, 4800, 7200, 9600, 19200, 38400, 57600, 115200, 230.4k, 460.8k, 921.6k
Data Bits
5, 6, 7, 8
Stop Bits
1, 1.5, 2
Parity
None, Even, Odd, Space, Mark
Flow Control
RTS/CTS (RS-232 only), DTR/DSR (RS-232 only), XON/XOFF
Isolation
2 kV isolation for NPort 5430I/5450I/5450I-T
Pull High/Low Resistor for RS-485
1 kilo-ohm, 150 kilo-ohms
RS-485 Data Direction Control
ADDC (automatic data direction control)
Terminator for RS-485
120 ohms
Serial Signals
RS-232
TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422
Tx+, Tx-, Rx+, Rx-, GND
RS-485-4w
Tx+, Tx-, Rx+, Rx-, GND
RS-485-2w
Data+, Data-, GND
Power Parameters
Input Current
NPort 5410/5450/5450-T: 350 mA @ 12 VDC
NPort 5430: 320 mA @ 12 VDC
NPort 5430I: 530 mA @ 12 VDC
NPort 5450I/5450I-T: 554 mA @ 12 VDCInput Voltage
12 to 48 VDC
No. of Power Inputs
2
Power Connector
1 removable 3-contact terminal block(s)
Power input jack
Reliability
Automatic Reboot Trigger
Built-in WDT
Alert Tools
Built-in buzzer and RTC (real-time clock)
Physical Characteristics
Housing
Metal
Dimensions (with ears)
181 x 103 x 33 mm (7.14 x 4.06 x 1.30 in)
Dimensions (without ears)
158 x 103 x 33 mm (6.22 x 4.06 x 1.30 in)
Weight
740 g (1.63 lb)
Interactive Interface
LCD panel display (standard temp. models only)
Push buttons for configuration (standard temp. models only)Installation
Desktop, DIN-rail mounting (with optional kit), Wall mounting
Environmental Limits
Operating Temperature
Standard Models: 0 to 55 C (32 to 131 F)
Wide Temp. Models: -40 to 75 C (-40 to 167 F)Storage Temperature (package included)
-40 to 75 C (-40 to 167 F)
Ambient Relative Humidity
5 to 95% (non-condensing)
Standards and Certifications
EMC
EN 55032/24
EMI
CISPR 32, FCC Part 15B Class A
EMS
IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
IEC 61000-4-4 EFT: Power: 1 kV; Signal: 0.5 kV
IEC 61000-4-5 Surge: Power: 1 kV; Signal: 1 kV
IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m
IEC 61000-4-8 PFMF
IEC 61000-4-11Maritime
DNV-GL (standard temp. models only)
Medical
EN 60601-1-2 Class B, EN 55011 (NPort 5410/5450/5450I only)
Safety
UL 60950-1
MTBF
Time
NPort 5410: 310,331 hrs
NPort 5430/5430I: 265,650 hrs
NPort 5450/5450I: 206,903 hrsStandards
Telcordia (Bellcore) Standard TR/SR
Warranty
Warranty Period
5 years